Technical Parameter

Power supply: DC 3V(2 AAA Batteries)or USB power supply

   (5V portable power battery)

Measuring speed:   Total cholesterol 15 sec;Uric acid  5 sec;

Blood glucose 5 sec;Hemoglobin 5 sec; 

Measuring principle: Biosensor Technology;

Correcting code of Total cholesterol  test strips: 1-49;

Correcting code of uric acid  test strips: 1-49;

Correcting code of blood glucose test strips: 1-49;

Correcting code of Hemoglobin test strips: 1-49;

Measuring range:

Total cholesterol:100-400mg/dL(2.5-10mmol/L);

Uric Acid: 1.5-19.83mg/dL(90-1190μmol/L)

Blood glucose:20-600mg/dL(1.1-33.3mmo/L); hemoglobin:5-26g/dL

Sample volume: blood sample about 1-2µL blood;

Sample: capillary whole blood and venous whole blood;

Size: 110mm×59mm×16mm

Warranty: 5 years;

Weight: 110g


Precautions to Obtain Accurate Results

Keep the system Cleaned and Disinfected 

Don’t smear the blood sample.

Don’t use the expired test strip.

Match the code on the meter with the code on the test strip vial. Contact your healthcare professional regularly.

Warranty

MTUSBIO warrants to the original purchaser of the meter that your   meter will be free from defects in materials and workmanship for five 

years from the date of purchase. If, during this five-year period, the meter does 

not work properly because of a defect in materials or workmanship, MTUSBIO 

will replace it with a new  meter free of charge. The warranty 

on the replacement meter will expire on the date of the original warranty expiration or 90 days after the shipment of a replacement system, whichever period is longer. The purchaser’s exclusive remedy with respect to the  meter shall be replacement.        

This warranty does not apply to the performance of an  meter 

that has been damaged by accident or has been altered, misused, tampered with, or abused in any way. Guangzhou MicroTUS International Biotechnology 

Co., Ltd. will handle meters that show damage or abuse according to its Non-Warranty Service Policy described on the following page.The above warranty is exclusive of all other warranties, and MTUSBIO makes no other warranties, express or implied, including without limitaion, the implied warranty of merchantability or fitness for a particular purpose. 

In no event shall Guangzhou MicroTUS International Biotechnology Co.,

Ltd. be liable to the purchaser or any other person for any incidental,

consequential, indirect, special, or punitive damages arising from or in

any way connected with the purchase or operation of the meter or its

parts. No warranty of merchantability or fitness for a particaular purpose,

if any is implied from the sales of the meter, shall extend for a longer

duration than three years from the date of purchase.